Haemorrhage
Because of their large bore and relative inflexibility, these lines have greater potential to cause blood vessel damage and bleeding than a standard central line. Haemorrhage can occur due to vessel tears at the time of insertion, or due to traumatic erosion of the vessel wall during use. Adult case series give a haemorrhage risk of approximately 2.5-3% per 100 line days from this type of line.
Clot
These lines can completely occlude the great veins in smaller patients, leading to venous stasis, congestion and risk of venous thrombosis. The lines themselves can also become obstructed with clot, particularly during periods of non-use, or conditions of marginal flow or under-anticoagulation. Care should be taken to HepLock the lines when not in use (see separate document: YOR-REN-001) and to ensure good blood flow and adequate anticoagulation during use.
Deep venous thrombosis is also a major risk during interruptions in extracorporeal therapy. For patients who are under 5kg in weight, or who are in a prothrombotic state, or who have a vessel diameter <5mm, serious consideration should be given to continuing systemic anticoagulation during breaks in therapy while the line remains in situ.
Misplacement
Our institutional experience shows that even highly experienced operators can misplace these lines during the insertion process. This is a particular risk with internal jugular placement, where lines can penetrate the carotid artery, the dome of the pleura, the right atrial wall or the deeper mediastinal tissues.
Migration/Displacement
After placement, lines can migrate & become displaced, particularly in mobile patients. Non-tunnelled lines are particularly susceptible to displacement due to changes in patient position or superficial tissue oedema causing the line to pull back. Lines can also erode the wall of the great veins or the right atrium, causing haemorrhage and/or tamponade.
Kinking/fracture
These lines are designed to be quite rigid in order to withstand negative hydrostatic pressures. This rigidity gives the line plastic a ‘memory’ and makes them prone to kinking. This is a particular risk for mobile patients with a line in the femoral position, where repeated flexing of the hip joint will cause kinking over time. Kinked lines can fracture, causing haemorrhage, bloodstream infection risk and/or air embolism. They should therefore be exchanged for a new line as soon as significant kinking is discovered. Consideration should be given to a tunnelled upper body line in such cases.
Infection
All central venous lines present a risk for Central Line-Associated Bloodstream Infection (CLABSI). Insertion should follow the infection prevention procedures laid down in the central venous access checklist. During subsequent use and routine maintenance, standard handwashing and central venous access hygiene procedures must be followed to reduce this risk. The line should be removed at the earliest possible opportunity after it is no longer needed.